RG 11
| Mechanical Data |
RG11 ST |
|
RG11 DF |
|
RG11 DS/J |
|
RG11 DF/M |
|
| |
|
|
|
|
| Inner Conductor |
CCS |
CCS |
CCS |
CCS |
| nominal diam.mm |
1.63 |
1.63 |
1.63 |
1.63 |
| Dielectric |
PEE |
PEE |
PEE |
PEE |
| nominal diam.mm |
7.11 |
7.11 |
7.11 |
7.11 |
| Shield |
|
|
|
|
| Foil |
al/pet |
al/pet |
al/pet |
al/pet |
| Braid |
AL |
AL |
AL |
AL |
| nominal diam.mm |
0.16 |
0.16 |
0.16 |
0.16 |
| braid coverage% |
60 |
60 |
60 |
60 |
| 2″ Foil |
|
|
|
|
| 2″ Braid |
|
|
|
|
| nominal diam.mm |
|
|
|
|
| braid coverage% |
|
|
|
|
| Jacket |
PVC |
PVC |
PVC |
PVC |
| nominal diam.mm |
10.03 |
10.03 |
10.3 |
10.3 |
| Messenger or Jelly |
|
|
jelly |
steel |
| nominal dia.mm |
|
|
|
1.83 |
| Mechanical Properties |
RG11 ST |
|
RG11 DF |
|
RG11 DS/J |
|
RG11 DF/M |
|
| Cable temperature rating |
70 |
|
70 |
|
70 |
|
70 |
|
| Jacket break point Mpa |
>10.34 |
|
>10.34 |
|
>10.34 |
|
>10.34 |
|
| Min bending radius |
20xO.D. |
|
20xO.D. |
|
20xO.D. |
|
20xO.D. |
|
| Electrical Properties |
|
|
|
|
|
|
|
|
| Sparker test Vac |
3000 |
|
3000 |
|
3000 |
|
3000 |
|
| Dielectric strenght Vac |
2500 |
|
2500 |
|
2500 |
|
2500 |
|
| Impedance |
75+-3 |
|
75+-3 |
|
75+-3 |
|
75+-3 |
|
| Capacitance pF/m |
52+-2 |
|
52+-2 |
|
52+-2 |
|
52+-2 |
|
| Velocity of propagation% |
85 |
|
85 |
|
85 |
|
85 |
|
| SRL 5-1000MHz |
>22 |
|
>22 |
|
>22 |
|
>22 |
|
| 1000-3000MHz |
20 |
|
20 |
|
20 |
|
20 |
|
| Attenuation |
|
|
|
|
|
|
|
|
| [@68º F. (20ºC)] |
(MHz) |
|
(dB/100m) |
|
(MHz) |
|
(dB/100m) |
|
| |
5 |
|
1.25 |
|
865 |
|
13.05 |
|
| |
55 |
|
3.15 |
|
1000 |
|
14.72 |
|
| |
250 |
|
6.72 |
|
|
|
|
|
| |
450 |
|
9.02 |
|
|
|
|
|
| |
550 |
|
9.97 |
|
|
|
|
|
| |
750 |
|
11.97 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|